Diabetes Care

Self-monitoring blood glucose provides useful information for diabetes management.

FORA® 6 Series

Multi-functional Monitoring System — Measures six parameters

FORA® Diamond Series

Blood Glucose Monitoring System (GDH-FAD)

FORA® COMFORT Series

Blood Glucose Monitoring System

FORA® COMFORT Series

Blood Glucose Monitoring System (GDH-FAD)

PROFESSIONAL Series

Blood Glucose and ß-ketone Monitoring System

Meters

Name FORA 6 Plus FORA 6 Connect FORA 6 GTel
Model Number GD81 GD82 GD84
Test Strips Blood Glucose, 3-in-1
(BG/HCT/BG), β-Ketone, Uric
Acid and Total Cholesterol
Blood Glucose, 3-in-1
(BG/HCT/BG), β-Ketone, Uric
Acid and Total Cholesterol
Blood Glucose, 3-in-1
(BG/HCT/BG), β-Ketone, Uric
Acid and Total Cholesterol
Universal Tone Yes Yes No
Talking Guidance No No Yes
Button Design No No Yes
Two Way Message No No Yes
Encouraging Reminder No No Yes
Service Button No No Yes
Trends and Graphs No No Yes
Memory Capacity 1,000 memory sets 1,000 memory sets 1,000 memory sets
Strip Ejection Yes Yes Yes
Strip Feed Light Yes Yes Yes
Daily Alarm 4 Alarms 4 Alarms 4 Alarms
Ketone Warning Yes, if ≥ 240 mg/dL Yes, if ≥ 240 mg/dL Yes, if ≥ 240 mg/dL
Meal Tag AutoQC mode; GEN / AC / PC AutoQC mode; GEN / AC / PC Before Meal / After Meal / No Tag
7, 14, 21, 28, 60, 29 – Day Average Yes Yes Yes
Display LCD Backlight LCD Backlight Color Touch Screen
Data Connection USB-Strip Port COM Cable Bluetooth 4.0 SIM (3G/4G)
Power Source AAA x 1 AAA x 1 Li-Polymer Battery

Test Strips

Strip Type Blood Glucose (BG) BG/HCT/HB β-ketone (KB) Uric Acid (UA) Total Cholesterol (TCH)
Enzyme Type GDH-FAD β-Hydroxybutyrate Dehydrogenase Uric Acid Catalyst
Cholesterol Esterase
Cholesterol Oxidase
Blood Sample Requirement 0.5 μL 0.8 μL 1.0 μL 3.0 μL
Reaction Time 5 Seconds 10 Seconds 15 Seconds 60 Seconds
Measurement Range
100 ~ 600mg/dL BG: 10 ~ 600 mg/dL
(0.55 ~ 33.3 mmol/L) HB: 0 ~ 23.8 g/dL
0.1 ~ 8.0 mmol/L 3 ~ 20 mg/dL 100 ~ 400 mg/dL
Hematocrit Range 0 ~ 70% 10 ~ 70% 20 ~ 60% 20 ~ 60%
Precision
SD < 5 mg/dL (0.278 mmol/L) if < 100
mg/dL (5.55 mmol/L);
CV < 5% if ≥ 100 mg/dL (5.55 mmol/L)
≤ 1 mmol/L, SD <0.1mM;
> 1 mmol/L, CV < 7.5%
CV < 7.5% CV < 7.5%
Accuracy ± 15mg/dL if < 100 mg/dL; ± 15% if ≥ 100
mg/dL
Alternative Site Testing (AST) Fingertips, Palm, Upper Arm or Forearm Not Applicable Not Applicable Not Applicable
Applicable Sample Type Capillary; Venous Capillary; Venous Capillary; Venous Capillary; Venous
Storage Condition 2°C (36.6°F) ~ 30°C (86.0°F); RH < 90% 2°C (36.6°F) ~ 30°C (86.0°F);
RH < 85%
2°C (36.6°F) ~ 30°C
(86.0°F); RH < 85%
2°C (36.6°F) ~ 30°C
(86.0°F); RH < 85%
Strip Pack Vial / Individual Pack Vial / Individual Pack Vial / Individual Pack Vial / Individual Pack Vial / Individual Pack
Shelf Life Time 24M / 18M 24M / 18M 18M 18M 18M

To Know More, Get in Touch With Us